SẢN PHẨM

  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" ANSI B16.5 class 150 RF Measur. range f. liquids: 10 - 100 L/h (0.044 - 0.44 gpm); Measur. range f. gases: 0.3 - 3 m3/h (0.177 - 1.77 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration without calibration certificate
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" ANSI B16.5 class 150 RF Measur. range f. liquids: 16 - 160 L/h (0.07 - 0.7 gpm); Measur. range f. gases: 0.5 - 4.6 m3/h (0.29 - 2.71 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration without calibration certificate
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" ANSI B16.5 class 300 RF Measur. range f. liquids: 60 - 600 L/h (0.264 - 2.64 gpm); Measur. range f. gases: 1.7 - 17 m3/h (1 - 10 scfm); Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration with calibration report (5 calibration points)
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 32 / ANSI 1 1/4" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 5 - 50 L/h (0.022 - 0.22 gpm); Measur. range f. gases: 0.15 - 1.5 m3/h(0.0883 - 0.883 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART Standard calibration with calibration report (5 calibration points) With ATEX approval Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 32 / ANSI 1 1/4" EN 1092-1 PN 100 Form B2 Measur. range f. liquids: 25 - 250 L/h (0.11 - 1.10 gpm); Measur. range f. gases: 0.7 - 7.0 m3/h (0.412 - 4.12 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: FF-P, Fitting: SST 1.4404 /316L, Flange: SST 1.4404/316L with PTFE liner Float: PTFE Nominal diameter flange: DN 25 / ANSI 1" ANSI B16.5 class 150 RF Measur. range f. liquids: 60 - 600 L/h (0.264 - 2.64 gpm); Measur. range f. gases: 1.7 - 17 m3/h (1 - 10 scfm); Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART Standard calibration with calibration report (5 calibration points) Name plate in English Factory certificate 2.2 (EN 10204) - wetted parts Inspection certificate 3.1 (EN 10204) - material of pressure-containing and wetted parts With ATEX approval Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure Tag (device parameter, max. 32 characters), plate, stainless steel 304/1.4301
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 1000 -4000 l/h Gas: 30 - 110 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 400 - 4000 L/h (1.76 - 17.6 gpm); Measur. range f. gases: 11 - 110 m3/h (6.47 - 64.74 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration with calibration report (5 calibration points)
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 1000 -4000 l/h Gas: 30 - 110 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 400 - 4000 L/h (1.76 - 17.6 gpm); Measur. range f. gases: 11 - 110 m3/h (6.47 - 64.74 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration without calibration certificate
    Tải Xuống:
  • SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 1000 -4000 l/h Gas: 30 - 110 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 40 / ANSI 1 1/2" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 160 - 1600 L/h (0.7 - 7 gpm); Measur. range f. gases: 4 - 46 m3/h (2.35 - 27.07 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
    Tải Xuống:
0985225604