SẢN PHẨM
-
SITRANS FM Transmag 911/E Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 1000 (1/2" to 40"), AC-excited. Suitable for volume flow measurement of liquids (conductive), for use in heavy-duty applications like pulp & paper stock over 3%, mining slurries with magnetic particles. Remote DN200, 8 Inch EN 1092-1, PN 25 (DN 200 - 600 (8 Inch - 24 Inch)) Flange material: Stainless steel flanges (1.4571/316Ti) Liner material: Soft rubber Hastelloy C276 / 2.4819 . . Metric:Polyamid Terminalbox
Tải Xuống: -
184,646,000VND106,578,000VNDSITRANS FM Transmag 911/E Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 1000 (1/2" to 40"), AC-excited. Suitable for volume flow measurement of liquids (conductive), for use in heavy-duty applications like pulp & paper stock over 3%, mining slurries with magnetic particles. Remote DN250, 10 Inch EN 1092-1, PN 16 (DN 65 - 1000 (2 1/2 Inch - 40 Inch)) Flange material: Mild steel 1.0460 / 1.0570) Liner material: Soft rubber Hastelloy C276 / 2.4819 . . Metric:Polyamid Terminalbox
Tải Xuống: -
207,223,000VND119,609,000VNDSITRANS FM Transmag 911/E Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 1000 (1/2" to 40"), AC-excited. Suitable for volume flow measurement of liquids (conductive), for use in heavy-duty applications like pulp & paper stock over 3%, mining slurries with magnetic particles. Remote DN250, 10 Inch EN 1092-1, PN 25 (DN 200 - 600 (8 Inch - 24 Inch)) Flange material: Mild steel 1.0460 / 1.0570) Liner material: Soft rubber Hastelloy C276 / 2.4819 . . Metric:Polyamid Terminalbox
Tải Xuống: -
262,738,000VND151,653,000VNDSITRANS FM Transmag 911/E Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 1000 (1/2" to 40"), AC-excited. Suitable for volume flow measurement of liquids (conductive), for use in heavy-duty applications like pulp & paper stock over 3%, mining slurries with magnetic particles. Remote DN300, 12 Inch EN 1092-1, PN 16 (DN 65 - 1000 (2 1/2 Inch - 40 Inch)) Flange material: Mild steel 1.0460 / 1.0570) Liner material: Linatex Hastelloy C276 / 2.4819 . . Metric:Polyamid Terminalbox
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 5 -40 l/h Gas: 0,15 - 1,3 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 15 / ANSI 1/2" EN 1092-1 PN 100 Form B2 Measur. range f. liquids: 1 - 10 L/h(0.0044 - 0.044 gpm); Measur. range f. gases: 0.03 -0.3 m3/h (0.018 - 0.18 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 15 / ANSI 1/2" ANSI B16.5 class 150 RF Measur. range f. liquids: 40 - 400 L/h (0.176 - 1.76 gpm); Measur. range f. gases: 1.0 - 11 m3/h (0.589 - 6.47 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration with calibration report (5 calibration points)
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 15 / ANSI 1/2" ANSI B16.5 class 150 RF Measur. range f. liquids: 60 - 600 L/h (0.264 - 2.64 gpm); Measur. range f. gases: 1.7 - 17 m3/h (1 - 10 scfm); Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration with calibration report (5 calibration points)
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 15 / ANSI 1/2" ANSI B16.5 class 300 RF Measur. range f. liquids: 60 - 600 L/h (0.264 - 2.64 gpm); Measur. range f. gases: 1.7 - 17 m3/h (1 - 10 scfm); Stainless steel IP66 - Up to 200°C with local display / 150 °C with electrical output Without heating sheath With local display, 4-20 mA HART Standard calibration without calibration certificate
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 10 - 100 L/h (0.044 - 0.44 gpm); Measur. range f. gases: 0.3 - 3 m3/h (0.177 - 1.77 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 60 - 600 L/h (0.264 - 2.64 gpm); Measur. range f. gases: 1.7 - 17 m3/h (1 - 10 scfm); Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 50 -600 l/h Gas: 1,5 - 17 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 25 / ANSI 1" EN 1092-1 PN 100 Form B2 Measur. range f. liquids: 10 - 100 L/h (0.044 - 0.44 gpm); Measur. range f. gases: 0.3 - 3 m3/h (0.177 - 1.77 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
Tải Xuống: