SẢN PHẨM

  • 113,621,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN125 (5"") Carbon Steel," EN 1434, qp=200m3/h, qs=280m3/h, qi=2m3/h MID 004 variant EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 2.5 L/p (not suitable for FUE950 with nominal size 1T up to 2K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 131,625,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN150 (6"") Carbon Steel," EN 1434, qp=150m3/h, qs=300m3/h, qi=3m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 5 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 1 L/p (not suitable for FUE950 with nominal size 1K up to 2B) with 4-20 mA analog output Power supply 115 - 230V AC. Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 123,822,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN150 (6"") Carbon Steel," EN 1434, qp=150m3/h, qs=300m3/h, qi=3m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 121,871,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN150 (6"") Carbon Steel," EN 1434, qp=150m3/h, qs=420m3/h, qi=3m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 5 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 123,822,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN150 (6"") Carbon Steel," EN 1434, qp=300m3/h, qs=420m3/h, qi=3m3/h MID 004 variant EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 150,748,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN150 (6"") Carbon Steel," EN 1434, qp=300m3/h, qs=420m3/h, qi=3m3/h MID 004 variant EN1092-1 PN40 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) With EU type examination certificate For measurements that are subject to billing within Europe Calibrated according to MID specification Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 3.6V DC Lithium battery, dual pack is included Marking for Standard device with EU type examination certificate (MI004) Language on nameplate English Pulse width: 5 ms
  • 147,135,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN200 (8"") Carbon Steel," EN 1434, qp=250m3/h, qs=500m3/h, qi=5m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 5 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) with 4-20 mA analog output Power supply 115 - 230V AC. Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 137,381,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN200 (8"") Carbon Steel," EN 1434, qp=250m3/h, qs=700m3/h, qi=5m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 5 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 147,806,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN200 (8"") Carbon Steel," EN 1434, qp=500m3/h, qs=700m3/h, qi=5m3/h MID 004 variant EN1092-1 PN25 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN250 (10"") Carbon Steel," EN 1434, qp=400m3/h, qs=1120m3/h, qi=8m3/h EN1092-1 PN16 Compact version, max. 120 °C (248 °F) With EU type examination certificate For measurements that are subject to billing within Europe Calibrated according to MID specification Impulswert: 100 L/p (not suitable for FUE950 with nominal size 4H up to 5V) Power supply 115 - 230V AC Marking for Standard device with EU type examination certificate (MI004) Language on nameplate French Pulse width: 100 ms
  • 160,534,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN250 (10"") Carbon Steel," EN 1434, qp=400m3/h, qs=1120m3/h, qi=8m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 5 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
  • 169,935,000VND
    SITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN250 (10"") Carbon Steel," EN 1434, qp=800m3/h, qs=1120m3/h, qi=8m3/h MID 004 variant EN1092-1 PN16 Compact version, max. 120 °C (248 °F) With EU type examination certificate For measurements that are subject to billing within Europe Calibrated according to MID specification Impulswert: 100 L/p (not suitable for FUE950 with nominal size 4H up to 5V) Power supply 115 - 230V AC Marking for Standard device with EU type examination certificate (MI004) Language on nameplate French Pulse width: 100 ms
0985225604
0985225604