172,014,000VNDSITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN250 (10"") Carbon Steel," EN 1434, qp=800m3/h, qs=1120m3/h, qi=8m3/h MID 004 variant EN1092-1 PN25 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 10 L/p (not suitable for FUE950 with nominal size 2K up to 3K) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
-
203,865,000VNDSITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN300 (12"") Carbon Steel," EN 1434, qp=1120m3/h, qs=1560m3/h, qi=11.2m3/h MID 004 variant EN1092-1 PN25 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 50 L/p (not suitable for FUE950 with nominal size 3L up to 5V) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
-
245,278,000VNDSITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN350 (14"") Carbon Steel," EN 1434, qp=1500m3/h, qs=2100m3/h, qi=15m3/h MID 004 variant EN1092-1 PN25 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 50 L/p (not suitable for FUE950 with nominal size 3L up to 5V) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
-
285,539,000VNDSITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN400 (16"") Carbon Steel," EN 1434, qp=950m3/h, qs=2660m3/h, qi=19m3/h EN1092-1 PN25 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 50 L/p (not suitable for FUE950 with nominal size 3L up to 5V) Power supply 115 - 230V AC Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
-
408,178,000VNDSITRANS FUE380 Mains or battery-operated ultrasonic In-Line flowmeter, diameter DN 50 to DN 1200 (2" to 48"), custody transfer approved. Suitable for volume flow and thermal energy measurement of liquids, for use in custody transfer metering in district heating plants, local networks, boiler stations, chiller plants. Siemens "DN700 (28"") Carbon Steel," EN 1434, qp=2900m3/h, qs=5800m3/h, qi=58m3/h EN1092-1 PN16 Remote version, Sensor link cabel (SSL) 10 m, with gland, DN50 to DN80: max. 150°C (302°F), DN100 to DN800 max. 200°C (392°F) Without EU type approval Standard device for operational measurements with high requirements Calibration according to selection pipe size / flow range Impulswert: 100 L/p (not suitable for FUE950 with nominal size 4H up to 5V) Power supply 115 - 230V AC, Backup: 3.6V DC Lithium battery, single pack is included Marking for standard device without type approval Language on nameplate English Pulse width: 5 ms
-
11,992,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 1 L/Pulse, max. flow rate 360 m3/h (with option L05: 1 gal/p., max. flow rate 6000 GPM). For heating applications, Flowmeter placed at low temperture (MID conform). Without sensor, Set-up: PT500 No thermowells included. Power supply Mains powered with 230 VAC module (incl. back-up battery). No in-/output modules MWh, kW, m3, m3/h - 1 digit resolution. Calculator variant for China according to EU type approval Suitable for billing of heat quantities (also combined) if national approvals exist. Not for use in Europe.
-
21,298,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 1 L/Pulse, max. flow rate 360 m3/h (with option L05: 1 gal/p., max. flow rate 6000 GPM). For heating applications, Flowmeter placed at low temperture (MID conform). PT500 sensor pair (6/50 mm), with EN1434 approval, 2-wire with 5 m connection cable, Sensor with 6 mm diameter and 50 mm length. Brass pockets for 6 mm 2-wire sensors, 82/92 mm - G1/2", max. PN16 & 1 m/s, (2 pcs.). Power supply Mains powered with 230 VAC module (incl. back-up battery). Module 1 M-Bus. MWh, kW, m3, m3/h - 2 digit resolution. Calculator without EU type approval. For operational measurements in heat or cold applications.
-
11,992,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 2.5 L/Pulse, max. flow rate 900 m3/h (with option L05: 2.5 gal/p., max. flow rate 15000 GPM). For heating applications, Flowmeter placed at low temperture (MID conform). Without sensor, Set-up: PT500 No thermowells included. Power supply Mains powered with 230 VAC module (incl. back-up battery). No in-/output modules MWh, kW, m3, m3/h - 1 digit resolution. Calculator variant for China according to EU type approval Suitable for billing of heat quantities (also combined) if national approvals exist. Not for use in Europe.
-
14,007,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 2.5 L/Pulse, max. flow rate 900 m3/h (with option L05: 2.5 gal/p., max. flow rate 15000 GPM). For heating applications, Flowmeter placed at hot temperture (MID conform). Without sensor, Set-up: PT500 No thermowells included. Power supply Mains powered with 230 VAC module (incl. back-up battery). Module 1 M-Bus. MWh, kW, m3, m3/h - 1 digit resolution. Calculator variant for China according to EU type approval Suitable for billing of heat quantities (also combined) if national approvals exist. Not for use in Europe.
-
25,072,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 5 L/Pulse, max. flow rate 1800 m3/h (with option L05: 5 gal/p., max. flow rate 30000 GPM). For cooling applications, Flowmeter placed at low temperture. PT500 sensor pair (6/50 mm), with EN1434 approval, 2-wire with 5 m connection cable, Sensor with 6 mm diameter and 50 mm length. Brass pockets for 6 mm 2-wire sensors, 82/92 mm - G1/2", max. PN16 & 1 m/s, (2 pcs.). Power supply Mains powered with 230 VAC module (incl. back-up battery). Module 1 RS-232 (M-Bus). Module 2 Pulse 2 outputs. MWh, kW, m3, m3/h - 2 digit resolution. Calculator without EU type approval. For operational measurements in heat or cold applications.
-
27,981,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 5 L/Pulse, max. flow rate 1800 m3/h (with option L05: 5 gal/p., max. flow rate 30000 GPM). For cooling applications, Flowmeter placed at low temperture. PT500 sensor pair (6/50 mm), with EN1434 approval, 2-wire with 10 m connection cable, Sensor with 6 mm diameter and 50 mm length. Brass pockets for 6 mm 2-wire sensors, 82/92 mm - G1/2", max. PN16 & 1 m/s, (2 pcs.). Power supply Mains powered with 230 VAC module (incl. back-up battery). Module 1 RS-232 (M-Bus). Module 2 Pulse 2 outputs. MWh, kW, m3, m3/h - 2 digit resolution. Calculator without EU type approval. For operational measurements in heat or cold applications.
-
14,007,000VNDSITRANS FUE950 Custody transfer approved energy calculator, for use with flow meters of type FUS380, FUE380, MAG 8000, FS220 and MAG 5000/6000 transmitter. Suitable for thermal energy measurement of liquids for applications in district heating and chiller plants. - Pulse value 10 L/Pulse, max. flow rate 3600 m3/h (with option L05: 10 gal/p., max. flow rate 60000 GPM). For heating applications, Flowmeter placed at low temperture (MID conform). Without sensor, Set-up: PT500 No thermowells included. Power supply Mains powered with 230 VAC module (incl. back-up battery). Module 1 M-Bus. Gcal, kW, m3, m3/h - 1 digit resolution. Calculator without EU type approval. For operational measurements in heat or cold applications.