SẢN PHẨM

  • 519,208,000VND
    SITRANS FCS300 dual tube Coriolis flowmeter, diameter DN 15 (1/2"), DN 25 (1"),DN 50 (2"), DN 80 (3"), DN 100 (4"),DN 150 (6"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor FCS300 with transmitter FCT030 Sensor size DN50 (2") with connection size DN50 (2") Weld neck flange EN1092-1 B1. Pressure PN40 AISI 316L, W1.4435/1.4404 Massflow: 0.1% Flow Density: 2kg/m3 Compact mounted transmitter Aluminium IP67 / NEMA 4X Standard. No Ex approvals on product. Graphical local user interface 240x160 pixels Lid window in "Panzer glass" Nylon cable glands metric thread Standard software (Transmitter) Current Output 4-20 mA HART active/passive Non-Ex No optional inputs and outputs on channels 2,3 and 4
  • SITRANS FCS300 dual tube Coriolis flowmeter, diameter DN 15 (1/2"), DN 25 (1"),DN 50 (2"), DN 80 (3"), DN 100 (4"),DN 150 (6"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases.
  • 1,465,653,000VND
    SITRANS FCS300 dual tube Coriolis flowmeter, diameter DN 15 (1/2"), DN 25 (1"),DN 50 (2"), DN 80 (3"), DN 100 (4"),DN 150 (6"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor FCS300 with transmitter FCT030 Sensor size DN100 (4") with connection size DN100 (4") Weld neck flange EN1092-1 B1. Pressure PN16 AISI 316L, W1.4435/1.4404 Massflow: 0.1% Flow Density: 2kg/m3 Compact mounted transmitter Aluminium IP67 / NEMA 4X Standard. No Ex approvals on product. Graphical local user interface 240x160 pixels Lid window in "Panzer glass" Nylon cable glands metric thread Standard software (Transmitter) Current Output 4-20 mA HART active/passive Non-Ex No optional inputs and outputs on channels 2,3 and 4
  • 2,195,377,000VND
    SITRANS FCS300 dual tube Coriolis flowmeter, diameter DN 15 (1/2"), DN 25 (1"),DN 50 (2"), DN 80 (3"), DN 100 (4"),DN 150 (6"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor FCS300 with transmitter FCT030 Sensor size DN150 (6") with connection size DN150 (6") Weld neck flange EN1092-1 B1. Pressure PN16 AISI 316L, W1.4435/1.4404 Massflow: 0.1% Flow Density: 2kg/m3 Compact mounted transmitter Aluminium IP67 / NEMA 4X Standard. No Ex approvals on product. Graphical local user interface 240x160 pixels Lid window in "Panzer glass" Nylon cable glands metric thread Standard software (Transmitter) Current Output 4-20 mA HART active/passive Non-Ex No optional inputs and outputs on channels 2,3 and 4
  • 127,468,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 1.5 with connection size 1/4 inch, Pipe thread ISO228-1 G, pressure PN365 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 125 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 127,468,000VND 94,784,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 1.5 with connection size 1/4 inch, Pipe thread ISO228-1 G, pressure PN365 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 125 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 114,804,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 114,804,000VND 85,368,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 179,529,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN350 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. ATEX II 2GD zone 1. FCT010/030 Field mount; z1/z21. MASS2100/FC300: Analog remote sensor z0/z1 MASS2100: Digital remote/compact sensor z1. No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 179,529,000VND 133,498,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN350 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. ATEX II 2GD zone 1. FCT010/030 Field mount; z1/z21. MASS2100/FC300: Analog remote sensor z0/z1 MASS2100: Digital remote/compact sensor z1. No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 153,882,000VND
    SITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart FC300 Sensor DN4 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 115 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 10 meter analog signal cable 5 x 2 x 0.34 screened and twisted in pairs. Outside insulation blue PVC With two M20 connectors. Female/Female Sensor with SensorProm for MASS6000/SIFLOW transmitters
    Tải Xuống:
  • 0985225604
    0985225604