SẢN PHẨM
-
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") EN1092-1 Form B1, PN 40 Remote design, cable length with order code L** Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, blue General approval: World (CE) except: EAC, KCC, UKCA, CRN 10m (32ft) cable for remote design Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") EN1092-1 Form B1, PN 40 Remote design, cable length with order code L** Aluminium HART Communication Without Ex approval Integrated pressure sensor 16 bar Gasket material pressure sensor FPM (Viton) Density compensation for steam + Heat meter for saturated and superheated steam M20x1.5 cable glands (3 cable entries) in plastic, blue 10m (32ft) cable for remote design Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") EN1092-1 Form B1, PN 40 Remote design, cable length with order code L** Aluminium HART Communication ATEX II2 G - Ex ia IIC T6 ... T2 Gb Integrated pressure sensor 40 bar Gasket material pressure sensor FPM (Viton) Density compensation for gases, wet gases and mixed gases + FAD M20x1.5 cable glands (3 cable entries) in plastic, grey 50m (164ft) UV resistant cable for remote design Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, grey Tag plate, stainless steel 304/1.4301, 40x20 mm Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam 1/2" NPT conduit connection in stainless steel (3 cable entries, cable glands not included) Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication Without Ex approval Integrated pressure sensor 10 bar Gasket material pressure sensor FPM (Viton) Density compensation for steam + Heat meter for saturated and superheated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication ATEX II2 G - Ex ia IIC T6 ... T2 Gb Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, blue Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication ATEX II2 G - Ex d (ia Ga) IIC T6 ... T2 Gb Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) made of brass, Ex-d/t/nA approved Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Remote design, cable length with order code L** Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, grey Inspection certificate 3.1 (EN 10204) - pressure test Inspection certificate 3.1 (EN 10204) - material of pressure-containing and wetted parts General approval: World (CE) except: EAC, KCC, UKCA, CRN 15m (49ft) cable for remote design Tag plate, stainless steel 304/1.4301, 40x20 mm Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 150 Remote design, cable length with order code L** Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard + Heat meter for saturated steam and water 1/2" NPT conduit connection in stainless steel (3 cable entries, cable glands not included) 10m (32ft) cable for remote design Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN100 (4") - Sensor size DN100 (4") with connection size DN100 (4") ANSI B16.5 RF, class 300 Remote design, cable length with order code L** Aluminium HART Communication Without Ex approval Integrated pressure sensor 16 bar Gasket material pressure sensor FPM (Viton) Density compensation for steam + Heat meter for saturated and superheated steam 1/2" NPT conduit connection in stainless steel (3 cable entries, cable glands not included) General approval: World (CE) except: EAC, KCC, UKCA, CRN 15m (49ft) cable for remote design Tag plate, stainless steel 304/1.4301, 40x20 mm Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN150 (6") - Sensor size DN150 (6") with connection size DN150 (6") EN1092-1 Form B1, PN 16 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard + Heat meter for saturated steam and water M20x1.5 cable glands (3 cable entries) in plastic, grey Tag plate, stainless steel 304/1.4301, 40x20 mm Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: