SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN40 1R - Sensor size DN25 (1") with connection size DN40 (1 1/2") EN1092-1 Form B1, PN 40 Remote design, cable length with order code L** Aluminium HART Communication ATEX II2 G - Ex ia IIC T6 ... T2 Gb Integrated pressure sensor 40 bar Gasket material pressure sensor FPM (Viton) Density compensation for gases, wet gases and mixed gases + FAD M20x1.5 cable glands (3 cable entries) in plastic, grey 50m (164ft) UV resistant cable for remote design Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN50 2R - Sensor size DN25 (1") with connection size DN50 (2") EN1092-1 Form B1, PN 16 Compact design without cable Aluminium HART Communication Without Ex approval Integrated pressure sensor 16 bar Gasket material pressure sensor FPM (Viton) Density compensation for steam + Heat meter for saturated and superheated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN40 (1 1/2") - Sensor size DN40 (1 1/2") with connection size DN40 (1 1/2") EN1092-1 Form B1, PN 40 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN40 (1 1/2") - Sensor size DN40 (1 1/2") with connection size DN40 (1 1/2") EN1092-1 Form B1, PN 40 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN40 (1 1/2") - Sensor size DN40 (1 1/2") with connection size DN40 (1 1/2") EN1092-1 Form B1, PN 40 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (1 cable entry - 2 plugged) in plastic, grey Quality inspection certificate - 5 point factory calibration (IEC 60770-2) Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN40 (1 1/2") - Sensor size DN40 (1 1/2") with connection size DN40 (1 1/2") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN40 (1 1/2") - Sensor size DN40 (1 1/2") with connection size DN40 (1 1/2") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication Without Ex approval Integrated pressure sensor 10 bar Gasket material pressure sensor FPM (Viton) Density compensation for steam + Heat meter for saturated and superheated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN50 1R - Sensor size DN40 (1 1/2") with connection size DN50 (2") EN1092-1 Form B1, PN 40 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, grey Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN80 2R - Sensor size DN40 (1 1/2") with connection size DN80 (3") EN1092-1 Form B1, PN 63 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (1 cable entry - 2 plugged) in plastic, grey Quality inspection certificate - 5 point factory calibration (IEC 60770-2) Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN80 2R - Sensor size DN40 (1 1/2") with connection size DN80 (3") ANSI B16.5 RF, class 150 Compact design without cable Aluminium HART Communication Without Ex approval Integrated pressure sensor 10 bar Gasket material pressure sensor FPM (Viton) Density compensation for steam + Heat meter for saturated and superheated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN50 (2") - Sensor size DN50 (2") with connection DN50 (2") EN1092-1 Form B1, PN 16 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard - Uncompensated for gases, steam and liquids including temperature compensation for saturated steam M20x1.5 cable glands (3 cable entries) in plastic, grey General approval: World (CE) except: EAC, KCC, UKCA, CRN Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: -
SITRANS FX330 Vortex flowmeter, flanged design, diameter DN 15 to DN 300 (1/2" to 12"). Suitable for volume flow, pressure and temperature measurement of liquids, gases and steam, for applications like heat metering of steam and hot water, consumption of industrial gases, process controls of conductive and non-conductive liquids, safety-related measurement in SIL applications (SIL2). Standard version (without SIL approval) DN50 (2") - Sensor size DN50 (2") with connection DN50 (2") EN1092-1 Form B1, PN 16 Compact design without cable Aluminium HART Communication Without Ex approval Without integrated pressure sensor Standard + Heat meter for saturated steam and water M20x1.5 cable glands (3 cable entries) in plastic, grey Tag plate, stainless steel 304/1.4301, 40x20 mm Medium: Specify medium (Steam, gas, liquid or customized) Temperature: Specify operating temperature and unit Pressure: Specify operating pressure and unit Density: Specify density and units Viscosity: Specify viscosity and units Flow rate: Specify max. flow rate and unit
Tải Xuống: