SẢN PHẨM
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 90 - 240 V AC (50 / 60 Hz) . . . No Sensors No cables UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). PVC, 30 m (1000 feet) UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). PVC, 15 m (50 feet) UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). PVC, 61 m (200 feet) UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 No cables UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 PVC, 15 m (50 feet) UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). PVC, 6 m (20 feet) UL, CE, C-Tick
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Two line display, push button, incl. cable glands, Modbus (RTU), Outputs (passive): Current, Relay, Pulse Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). PVC, 15 m (50 feet) UL, CE, C-Tick
-
69,138,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . No Sensors No cables UL, ULc, CE, KC
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . No Sensors Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory) Cable termination kit, required for externally procured cables (F-connector / F angle adapter / shrink tubing)
-
134,887,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size A2, for any pipe material, outer diameter range: 12,7 - 50 mm (0.5 - 2"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
134,887,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
134,887,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Cable termination kit, required for externally procured cables (F-connector / F angle adapter / shrink tubing)
-
148,669,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Cable termination kit, required for externally procured cables (F-connector / F angle adapter / shrink tubing)
-
141,410,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
143,905,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
177,003,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
177,003,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
183,047,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
137,253,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair high precision size C2H, for steel pipe, pipe wall thickness: 5,8 - 8,1 mm (0.23 - 0.32"), temperature <80°C (<176°F) specified for -40°C bis 121°C (-40°F to 250°F), with mounting frame kit for pipes up to 610 mm (24"). No cables UL, ULc, CE, KC
-
147,582,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair high precision size C2H, for steel pipe, pipe wall thickness: 5,8 - 8,1 mm (0.23 - 0.32"), temperature <80°C (<176°F) specified for -40°C bis 121°C (-40°F to 250°F), with mounting frame kit for pipes up to 610 mm (24"). Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
264,401,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair universal high temperture Size 2 up to 230°C (446°F), for any pipe material, for pipe sizes 30 - 200 mm (1,5 - 8"), including mounting tracks for pipes up to 250 mm (10"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
264,401,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair universal high temperture Size 2 up to 230°C (446°F), for any pipe material, for pipe sizes 30 - 200 mm (1,5 - 8"), including mounting tracks for pipes up to 250 mm (10"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
69,138,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . No Sensors No cables UL, ULc, CE, KC
-
143,425,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
148,669,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
143,905,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
149,948,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
149,948,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
155,481,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 11,5 - 28,5 V DC . . . FSS200 Sensor pair high precision size A3H, for steel pipe, pipe wall thickness: 1,5 - 2 mm (0.06 - 0.8"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 127 mm (5"). Sensor cabels Coax PVC, submersible 30 m (98.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176°F) UL, ULc, CE, KC
-
129,802,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Without FST030 transmitter, for FS-DSL spare part or system for use with the SITRANS FST070 Sensor FSS200 for liquid on non steel / non plastic pipes, specification range: -40 ° C to + 121 ° C (-40 ° F to 250 ° F) Outer pipe diameter >305 - 508 mm (12.0 - 20.0 in) Pipe wall thickness >5.8 - 8.1 mm (0.23 - 0.32 in) Frames/tracks (aluminum) includes straps (frames and spacer-bar on pipes bigger 125 mm (5 inch)) Single Path (one sensor pair) Sensor: 7ME39505LE00 (FSS200, Uni D3C, Liquid) Standard External Digital Sensor Link without transmitter, aluminum - epoxy coated IP 66/67, NEMA 4X, for 1 - 4 path for SSL-cable M12-plug, 11 cable entries M20x1.5 thread No EX-approval No transmitter, external DSL only, without user interface None cable glands Standard Industry application (Liquids, e.g. water) No input /output channel No optional inputs and outputs Sensor cable set 1-pair to external DSL / transmitter, Coax cable submersible, 20 m (65.6 ft), with F-connector, shortenable, terminated on one end side, incl. cable gland Nylon M20 x1.5, gland sensor plastic, F-connector Enable Mass storage device function for SD-card by USB (outside USA nomally "yes").
Tải Xuống: -
129,514,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting For ordering a replacement transmitter/DSL For ordering a replacement transmitter/DSL Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands polyamide M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex Channel 2: non-Ex, activ/passiv Current/Freq./Pulse
Tải Xuống: -
132,840,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting For ordering a replacement transmitter/DSL For ordering a replacement transmitter/DSL Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands polyamide M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex Channel 2+3: non-Ex, activ/passiv Current/Freq./Pulse Enable Mass storage device function for SD-card by USB (outside USA nomally "yes").
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Single Path (one sensor pair) For ordering a replacement transmitter/DSL Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval No transmitter, external DSL only, without user interface
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Single Path (one sensor pair) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys NPT-adapters nickel plated brass 1/2inch to M20x1,5, 9 ea (for conduit connection) Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex No optional inputs and outputs
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Single Path (one sensor pair) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys NPT-adapters nickel plated brass 1/2inch to M20x1,5, 9 ea (for conduit connection) Standard Industry application (Liquids, e.g. water) Modbus RTU (RS485), no Ex, Ex Channel 2+3: non-Ex, activ/passiv Current/Freq./Pulse Channel 4: Relay
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Single Path (one sensor pair) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands nickel plated brass M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex No optional inputs and outputs
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Single Path (one sensor pair) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands polyamide M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex Channel 2+3: non-Ex, activ/passiv Current/Freq./Pulse Channel 4: Relay
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Single Path (one sensor pair) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands polyamide M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex Channel 2: non-Ex, activ/passiv Current/Freq./Pulse Channel 3: Relay
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Dual Path (two sensor pairs) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands nickel plated brass M20x1.5, 5 + 6 blind glands Hydrocarbon application (oil table with temperature and viscosity compensation) Modbus RTU (RS485), no Ex, Ex Channel 2+3+4: non-Ex, activ/passiv Current/Freq./Pulse Temperature sensor PT1000 platinum (Junction-Box-connected) submersible (Ex) Enable Mass storage device function for SD-card by USB (outside USA nomally "yes").
Tải Xuống: -
SITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 No sensor No sensor No sensor No sensor mounting Dual Path (two sensor pairs) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread ATEX: Sensors + external DSL Zone 0, 1 , 2; Wall mount enclosure Zone 2 Illuminated display sensor keys Cable glands nickel plated brass M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) Modbus RTU (RS485), no Ex, Ex Channel 2+3: Ex, activ Current/Freq./Pulse Channel 4: Relay Enable Mass storage device function for SD-card by USB (outside USA nomally "yes").
Tải Xuống: -
181,832,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 Sensor FSS200 for gas/liquid on steel /stainless steel pipes, optimized for average medium temperature below 80°C (176°F), specification range: -40°C to +121°C (-40°F to 250°F) Outer pipe diameter >13 - 19 mm (0.5 - 0.75 in) Pipe wall thickness >1.5 - 2.0 mm (0.06 - 0.08 in) Frames/tracks (aluminum) includes straps (frames and spacer-bar on pipes bigger 125 mm (5 inch)) Single Path (one sensor pair) Sensor: 7ME39505LB11 (FSS200, Uni A1C, Liquid) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys Cable glands polyamide M20x1.5, 5 + 6 blind glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex No optional inputs and outputs Sensor cable set 1-pair to external DSL / transmitter, Coax cable submersible, 10 m (32.8 ft), with F-connector, shortenable, terminated on one end side, incl. cable gland Nylon M20 x1.5, gland sensor plastic, F-connector Enable Mass storage device function for SD-card by USB (outside USA nomally "yes").
Tải Xuống: -
306,900,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 Sensor FSS200 for gas/liquid on steel /stainless steel pipes, optimized for average medium temperature below 80°C (176°F), specification range: -40°C to +121°C (-40°F to 250°F) Outer pipe diameter >13 - 19 mm (0.5 - 0.75 in) Pipe wall thickness >2.0 - 3.0 mm (0.08 - 0.12 in) Mounting straps slotted (stainless steel), includes spacer-bar (Aluminum) Single Path (one sensor pair) Sensor: 7ME39505LB01 (FSS200, Uni A2C, Liquid) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread IECEX: Sensors + external DSL Zone 0, 1 , 2; Wall mount enclosure Zone 2 Illuminated display sensor keys None cable glands Hydrocarbon application (oil table with temperature and viscosity compensation) Factory certification 2.2 to EN 10204:2004 HART, 4-20mA, Ex active Channel 2: Ex, passiv Current/Freq./Pulse Sensor cable set 1-pair to external DSL / transmitter, Coax cable submersible, 10 m (32.8 ft), with F-connector, shortenable, terminated on one end side, incl. cable gland Nickel Plated Brass M20 x1.5, gland sensor plastic, F-connector Enable Mass storage device function for SD-card by USB (outside USA nomally "yes").
Tải Xuống: -
165,458,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 Sensor FSS200 for gas/liquid on steel /stainless steel pipes, optimized for average medium temperature below 80°C (176°F), specification range: -40°C to +121°C (-40°F to 250°F) Outer pipe diameter >30.5 - 50.8 mm (1.2 - 2.0 in) Pipe wall thickness >4.1 - 5.8 mm (0.16 - 0.23 in) Frames/tracks (aluminum) includes straps (frames and spacer-bar on pipes bigger 125 mm (5 inch)) Single Path (one sensor pair) Sensor: 7ME39505LC01 (FSS200, Uni B3C, Liquid) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys None cable glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex No optional inputs and outputs
Tải Xuống: -
163,668,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 Sensor FSS200 for gas/liquid on steel /stainless steel pipes, optimized for average medium temperature below 80°C (176°F), specification range: -40°C to +121°C (-40°F to 250°F) Outer pipe diameter >50.8 - 76 mm (2.0 - 3.0 in) Pipe wall thickness >1.5 - 2.0 mm (0.06 - 0.08 in) Mounting straps slotted (stainless steel), includes spacer-bar (Aluminum) Single Path (one sensor pair) Sensor: 7ME39505LJ01 (FSS200, HP-A3HC, Liquid) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys None cable glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex No optional inputs and outputs
Tải Xuống: -
175,308,000VNDSITRANS FS230 Clamp-On Highly accurate flow meter in the industrial sector for water supply, for crude oil or petroleum products or for gas transport in pipelines Transmitter FST030 Sensor FSS200 for gas/liquid on steel /stainless steel pipes, optimized for average medium temperature below 80°C (176°F), specification range: -40°C to +121°C (-40°F to 250°F) Outer pipe diameter >50.8 - 76 mm (2.0 - 3.0 in) Pipe wall thickness >4.1 - 5.8 mm (0.16 - 0.23 in) Frames/tracks (aluminum) includes straps (frames and spacer-bar on pipes bigger 125 mm (5 inch)) Single Path (one sensor pair) Sensor: 7ME39505GM00 (FSS200, HP-C1HC-T1, Liquid/Gas) Standard Wall mount enclosure with internal DSL-modul, aluminum - epoxy coated IP 67, NEMA 4X, internal universal power supply 24 - 240 V DC/AC (50 / 60Hz), for 1 - 2 path 9 cable entries M20x1.5 thread No EX-approval Illuminated display sensor keys None cable glands Standard Industry application (Liquids, e.g. water) HART, 4-20mA, active/passive, non Ex No optional inputs and outputs
Tải Xuống: