SẢN PHẨM
-
62,455,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Wall mount, standard enclosure Input voltage: 12 to 30 VDC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC
Tải Xuống: -
62,455,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC
Tải Xuống: -
66,484,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III, EAC Ex Ex tc IIIC T75 °C Dc X (for wall mount applications only) Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000
Tải Xuống: -
73,423,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 100 to 230 VAC Number of measurement points: Dual point model, 6 relays Data Communications: Without module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC
Tải Xuống: -
62,455,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 12 to 30 VDC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC
Tải Xuống: -
93,698,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Wall mount, 4 entries, 4 M20 cable glands included Input voltage: 12 to 30 VDC Number of measurement points: Single point model, 6 relays Data Communications: Smartlinx PROFIBUS DP V0 module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC Manufacturer's Test Certificate: M to DIN 55350, Part 18 and to ISO 9000
Tải Xuống: -
76,302,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Panel Mount Input voltage: 100 to 230 VAC Number of measurement points: Dual point model, 6 relays Data Communications: Without module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC
Tải Xuống: -
65,333,000VNDHydroRanger 200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Mounting: 4 button HMI, Panel Mount Input voltage: 12 to 30 VDC Number of measurement points: Single point model, 6 relays Data Communications: Without module Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL Listed, RCM, EAC, KC
Tải Xuống: -
45,122,000VNDSITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC -
Tải Xuống: -
46,273,000VNDSITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC - Test Certificate: Manufacturer's test certificate M to DIN 55350, Part 18 and to ISO 9000
Tải Xuống: -
47,936,000VNDSITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, cable glands not supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Hazardous locations CSA Class I, II, III Division 2 (Groups A,B,C,D,F,G) -
Tải Xuống: -
45,729,000VNDSITRANS LUT400 Series Ultrasonic level controller: continuous, non-contact, 60 m (197 ft) range. Monitors level, volume, and volume flow in liquids, slurries, and solids. With high accuracy volume flow and built in data logging. - Model: SITRANS LUT420 - Level controller Enclosure Display Options: With display Input Voltage: 100 to 230 V AC +/- 15% Cable Inlet: 3 cable inlets, 3 M20 plastic cable glands supplied Number of measurement points: Single point system (includes one transducer input,one mA output and one external temperature sensor input) Communications & I/O: HART, 2 discrete inputs, 3 relays Approvals: Ordinary Locations/General Purpose (Non-Ex), CE, UKCA, FM, CCSAUS, UL, RCM, EAC, KC -
Tải Xuống: