SẢN PHẨM
-
44,951,000VND38,036,000VNDSITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN50, 2 Inch Clamp type connection fittings: DIN 32676 Ceramic EPDM (FDA) Electrode material: Platinum Sensor for remote transmitter (Order transmitter separately) No bus Communication 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
75,275,000VND63,694,000VNDSITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN50, 2 Inch Clamp type connection fittings: DIN 32676 Ceramic EPDM (FDA) Electrode material: Platinum MAG 6000, IP67 / NEMA 4X/6 Plastic enclosure, with display 11-30V DC/11-24V AC, 50/60 Hz No bus Communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
48,559,000VND41,088,000VNDSITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN50, 2 Inch Clamp type connection fittings: Tri-Clamp / BS 4825-3 PFA (no ATEX) EPDM (FDA) Hastelloy C22 / 2.4602 Sensor for remote transmitter (Order transmitter separately) No bus Communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
0VNDSITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN65, 2 1/2 Inch None (not 3A approved) PFA (no ATEX) EPDM (FDA) Hastelloy C22 / 2.4602 MAG 6000 I Aluminum 18 - 90V DC, 115 - 230V AC FM / CSA Class I Div. 2 No bus Communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
0VNDSITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN65, 2 1/2 Inch Clamp type connection fittings: DIN 32676 PFA (no ATEX) Gasket type P EPDM (FDA) only with PFA liner. Hastelloy C22 / 2.4602 MAG 6000 I Aluminum 18 - 90V DC, 115 - 230V AC FM / CSA Class I Div. 2 No bus Communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
51,640,000VND43,695,000VNDSITRANS FM MAG 1100 F Full-bore electromagnetic flow sensor, sanitary design, diameter DN 10 to DN 100 (3/8" to 4"). Suitable for volume flow measurement of liquids (conductive) , for applications in F&B, pharmaceutical industry. . DN65, 2 1/2 Inch Clamp type connection fittings: DIN 32676 Ceramic EPDM (FDA) Electrode material: Platinum Sensor for remote transmitter (Order transmitter separately) No bus Communication 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
38,644,000VND34,350,000VNDSITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN15, 1/2 Inch EN1092-1, PN40 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE Hastelloy C276 / 2.4819 (PFA: Hastelloy C22/2.4602) Sensor for remote transmitter (Order transmitter separately) No bus communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount Country of origin France
Tải Xuống: -
38,644,000VND34,350,000VNDSITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN15, 1/2 Inch EN1092-1, PN40 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE Hastelloy C276 / 2.4819 (PFA: Hastelloy C22/2.4602) Sensor for remote transmitter (Order transmitter separately) No bus communication 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
38,644,000VND34,350,000VNDSITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN15, 1/2 Inch EN1092-1, PN40 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE Hastelloy C276 / 2.4819 (PFA: Hastelloy C22/2.4602) Sensor for remote transmitter (Order transmitter separately) No bus communication 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount Country of origin France
Tải Xuống: -
65,390,000VND58,124,000VNDSITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN15, 1/2 Inch EN1092-1, PN40 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE Hastelloy C276 / 2.4819 (PFA: Hastelloy C22/2.4602) MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz No bus communication 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
65,390,000VND58,124,000VNDSITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN15, 1/2 Inch EN1092-1, PN40 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE Hastelloy C276 / 2.4819 (PFA: Hastelloy C22/2.4602) MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 115-230V AC 50/60 Hz No bus communication 1/2 inch NPT cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: -
59,029,000VND52,470,000VNDSITRANS FM MAG 3100 Full-bore electromagnetic flow sensor, flanged, diameter DN 15 to DN 2000 (1/2" to 78"). Suitable for volume flow measurement of liquids (conductive), main applications in process industry, chemical industry, steel industry, mining, utility, power generation and distribution, O&G/HPI. . DN15, 1/2 Inch EN1092-1, PN40 Carbon steel flanges ASTM A 105, corrosion-resistant coating of category C4 PTFE Platinum (not for Ebonite) Sensor for remote transmitter (Order transmitter separately) No bus communication Metric cable glands, Polyamid terminal box or MAG 6000i integral mount
Tải Xuống: