SẢN PHẨM
-
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 1000 -4000 l/h Gas: 30 - 110 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 40 / ANSI 1 1/2" ANSI B16.5 class 150 RF Measur. range f. liquids: 100 - 1000 L/h (0.44 - 4.4 gpm); Measur. range f. gases: 3 - 30 m3/h (1.77 - 17.66 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration without calibration certificate
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 2,5 -6,0 m3/h / Gas: 70 - 170 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 32 / ANSI 1 1/4" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 600 - 6000 L/h (2.64 - 26.4 gpm); Measur. range f. gases: 17 - 170 m3/h (10 - 100 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration without calibration certificate
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 2,5 -6,0 m3/h / Gas: 70 - 170 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 32 / ANSI 1 1/4" ANSI B16.5 class 150 RF Measur. range f. liquids: 400 - 4000 L/h (1.76 - 17.6 gpm); Measur. range f. gases: 11 - 110 m3/h (6.47 - 64.74 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART Standard calibration without calibration certificate
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 2,5 -6,0 m3/h / Gas: 70 - 170 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 40 / ANSI 1 1/2" ANSI B16.5 class 150 RF Measur. range f. liquids: 250 - 2500 L/h (1.1 - 11 gpm); Measur. range f. gases: 7 - 70 m3/h (4.12 - 41.2 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display, 4-20 mA HART, 1 limit switch, 1 pulse output Standard calibration without calibration certificate
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 2,5 -6,0 m3/h / Gas: 70 - 170 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 50 / ANSI 2" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 400 - 4000 L/h (1.76 - 17.6 gpm); Measur. range f. gases: 11 - 110 m3/h (6.47 - 64.74 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 4,0 -25,0 m3/h / Gas: 30 - 700 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 50 / ANSI 2" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 1000 - 10k L/h(4.4 - 44 gpm); Measur. range f. gases: 29 - 290 m3/h (17.1 - 170.7 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration with calibration report (5 calibration points)
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 4,0 -25,0 m3/h / Gas: 30 - 700 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 50 / ANSI 2" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 2000 - 20k L/h (8.8 - 88 gpm); Measur. range f. gases: 55 - 550 m3/h(32.4 - 323.7 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration with calibration report (5 calibration points)
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution.
Tải Xuống: -
SITRANS FVA250 Variable area flowmeter, diameter DN 15 to DN 100 (1/2" to 4"), full metal design. Suitable for volume flow measurement of liquids, gases and steam, for applications in chemical (industry, water, power) generation and distribution. Flow tube Liquid: 16 - 50 m3/h Gas: 460 - 1350 m3/h Flow tube Liquid: 16 - 50 m3/h Gas: 460 - 1350 m3/h Type: CF-S (standard), Fitting: SST 1.4404/316L, Flange: SST 1.4404/316L, Float: SST 1.4404 /316L Nominal diameter flange: DN 80 / ANSI 3" EN 1092-1 PN 40 Form B1 Measur. range f. liquids: 2500 - 25k L/h (11 - 110 gpm); Measur. range f. gases: 70 - 700 m3/h (41.2 - 412 scfm) Standard (aluminium) - Up to 200 °C with local display / 150 °C with electric output Without heating sheath With local display Standard calibration without calibration certificate Specify in plain text: fluid / flow range / density / viscosity / operating temperature / operating pressure
Tải Xuống: