SẢN PHẨM
-
134,887,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size B3, for any pipe material, outer diameter range: 19 - 127 mm (0.75 - 5"), temperature -40°C - +121°C (-40°F to 250°F), with mounting track kit for pipes up to 130 mm (5"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Cable termination kit, required for externally procured cables (F-connector / F angle adapter / shrink tubing)
-
148,669,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
SITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size C3, for any pipe material, outer diameter range: 51 - 305 mm (2 - 12"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 330 mm (13"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Cable termination kit, required for externally procured cables (F-connector / F angle adapter / shrink tubing)
-
141,410,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 5 m (16.4 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
143,905,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size D3, for any pipe material, outer diameter range: 203 - 610 mm (8 - 24"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 650 mm (25"). Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
177,003,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
177,003,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC Enable Mass storage device function for SD-card by USB (outside USA mandatory)
-
183,047,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair Uníversal size E2, for any pipe material, outer diameter range: 254 - 6096 mm (12 - 240"), temperature -40°C - +121°C (-40°F to 250°F), with mounting frame kit for pipes up to 1200 mm (48"). For pipes bigger 30" order separatly spacer bar extension 7ME3960-0MS40 Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
137,253,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair high precision size C2H, for steel pipe, pipe wall thickness: 5,8 - 8,1 mm (0.23 - 0.32"), temperature <80°C (<176°F) specified for -40°C bis 121°C (-40°F to 250°F), with mounting frame kit for pipes up to 610 mm (24"). No cables UL, ULc, CE, KC
-
147,582,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair high precision size C2H, for steel pipe, pipe wall thickness: 5,8 - 8,1 mm (0.23 - 0.32"), temperature <80°C (<176°F) specified for -40°C bis 121°C (-40°F to 250°F), with mounting frame kit for pipes up to 610 mm (24"). Sensor cabels Coax PVC, submersible 10 m (32.8 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC
-
264,401,000VNDSITRANS FS220 - Clamp On SITRANS FS220 1-path ultrasonic flow meter for volume measurement of liquids. For simple use in the areas of water and sewage, heating, ventilation and air conditioning technology. Ideal for retrofitting in water supply networks for leakage monitoring. Transmitter FST020 Graphical display highlighted with push button, Modbus (RTU), Outputs (passive): Current, Relay, Pulse, complete with cable glands Power supply: 90 - 240 V AC (50 / 60 Hz) . . . FSS200 Sensor pair universal high temperture Size 2 up to 230°C (446°F), for any pipe material, for pipe sizes 30 - 200 mm (1,5 - 8"), including mounting tracks for pipes up to 250 mm (10"). Sensor cabels Coax PVC, submersible 20 m (65.6 ft), with F-connector, shortenable terminated on one end side, -40° C to 80°C (-40°F to 176° F) UL, ULc, CE, KC