  • SITRANS FUS060 Ultrasonic flow transmitter, works with sensors of type SONO 3100, SONO 3300, SONO-KIT, up to a maximum of DN500. Suitable for volume flow measurement of water, die-cast aluminium enclosure. Siemens Transmitter for external use. Sparepart. Remote connection. Incl. mountingplate. Die cast aluminium housing . Supply: 115-230 V AC 50/60 Hz No Ex. Approval Local Display/Keypad HART, 4-20mA, Active or Passive Pulse, Relay. . Imperial: 1/2 Inch NPT for Supply, Output and Transducers.
  • SITRANS FUS060 Ultrasonic flow transmitter, works with sensors of type SONO 3100, SONO 3300, SONO-KIT, up to a maximum of DN500. Suitable for volume flow measurement of water, die-cast aluminium enclosure. Siemens Transmitter for external use. Sparepart. Remote connection. Incl. mountingplate. Die cast aluminium housing . Supply: 18-30 V DC No Ex. Approval Local Display/Keypad HART, 4-20mA, Active or Passive Pulse, Relay. . Metric: M25 / M20 x 1.5 for Supply and Output. Metric: M16 x 1.5 for Transducers.
  • SITRANS FUS060 Ultrasonic flow transmitter, works with sensors of type SONO 3100, SONO 3300, SONO-KIT, up to a maximum of DN500. Suitable for volume flow measurement of water, die-cast aluminium enclosure. Siemens Transmitter for external use. Sparepart. Remote connection. Incl. mountingplate. Die cast aluminium housing . Supply: 18-30 V DC No Ex. Approval Local Display/Keypad HART, 4-20mA, Active or Passive Pulse, Relay. . Imperial: 1/2 Inch NPT for Supply, Output and Transducers.
  • SITRANS FUS060 Ultrasonic flow transmitter, works with sensors of type SONO 3100, SONO 3300, SONO-KIT, up to a maximum of DN500. Suitable for volume flow measurement of water, die-cast aluminium enclosure. Siemens Transmitter for external use. Sparepart. Remote connection. Incl. mountingplate. Die cast aluminium housing . Supply: 18-30 V DC No Ex. Approval Local Display/Keypad Profibus PA, Passive Pulse. . Imperial: 1/2 Inch NPT for Supply, Output and Transducers.
  • SITRANS FUS060 Ultrasonic flow transmitter, works with sensors of type SONO 3100, SONO 3300, SONO-KIT, up to a maximum of DN500. Suitable for volume flow measurement of water, die-cast aluminium enclosure. Siemens Transmitter for external use. Sparepart. Remote connection. Incl. mountingplate. Die cast aluminium housing . Supply: 18-30 V DC ATEX II2 G Ex dem (ia/ib) IIC T6/T4/T3 Local Display/Keypad HART, Ex-version Ex. (ib), 4-20mA, Passive Pulse, Relay. . Metric: M25 / M20 x 1.5 for Supply and Output. Metric: M16 x 1.5 for Transducers.
  • SITRANS FUS SONO 3100/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 100 to DN 1200 (4" to 48"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, liquidcryogenic application, district heating systems. . DN300 / 12 Inch, Qn=850m3/h EN1092-1 PN10 Carbon Steel. EN 1.0345 P235GH, Painted. IP67 PA housing, PN40, O-ring, 50mm, 100deg.C. Cable Glands, M20 in Transducers and M25 / M20 / M16 in FUS060 Transmitter. SITRANS FUS060 Transmitter for remote connection. Supply: 115-230 V AC 50/60 Hz. HART, 4-20mA, Active or Passive Pulse, Relay. Transducer Cable: 4 * 15 meter, Max. 70deg.C
  • SITRANS FUS SONO 3100/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 100 to DN 1200 (4" to 48"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, liquidcryogenic application, district heating systems. . DN400 / 16 Inch, Qn=1300m3/h EN1092-1 PN16 Carbon Steel. EN 1.0345 P235GH, Painted. IP67 PA housing, PN40, O-ring, 50mm, 100deg.C. Cable Glands, M20 in Transducers and M25 / M20 / M16 in FUS060 Transmitter. SITRANS FUS060 Transmitter for remote connection. Supply: 115-230 V AC 50/60 Hz. HART, 4-20mA, Active or Passive Pulse, Relay. Transducer Cable: 4 * 15 meter, Max. 70deg.C
  • SITRANS FUS SONO 3100/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 100 to DN 1200 (4" to 48"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, liquidcryogenic application, district heating systems. . DN500 / 20 Inch, Qn=2200m3/h EN1092-1 PN16 Carbon Steel. EN 1.0345 P235GH, Painted. IP68 SS housing, PN40, O-ring, 50mm, 200deg.C. Cable Glands, M20 in Transducers and M25 / M20 / M16 in FUS060 Transmitter. SITRANS FUS060 Transmitter for remote connection. Supply: 115-230 V AC 50/60 Hz. HART, 4-20mA, Active or Passive Pulse, Relay. Teflon Transducer Cable 4 * 30 meter, Max. 200deg.C Inspection certificate 3.1 (EN 10204) - 100% NDT on weldings DN500 to DN600 Tag (device parameter, max. 20 characters), plate, stainless steel 304/1.4301
  • SITRANS FUS SONO 3100/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 100 to DN 1200 (4" to 48"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, liquidcryogenic application, district heating systems. . DN500 / 20 Inch, Qn=2200m3/h EN1092-1 PN40 Carbon Steel. EN 1.0345 P235GH, Painted. IP68 SS housing, PN40, O-ring, 50mm, 200deg.C. Cable Glands, M20 in Transducers and M25 / M20 / M16 in FUS060 Transmitter. SITRANS FUS060 Transmitter for remote connection. Supply: 24 V AC/DC. HART, 4-20mA, Active or Passive Pulse, Relay. Transducer Cable: 4 * 3 meter, Max. 70deg.C Optional Calibr./Verification Accredited Siemens ISO / IEC 17025 calibration. DN 200 to DN 600 with Qp as selected in diameter above. Certificate: 2x5 points at 5, 10, 25, 50 & 100% Qp (max 2800 m3/h). Inspection certificate 3.1 (EN 10204) Inspection certificate 3.1 (EN 10204) - pressure test KCC Tag (device parameter, max. 20 characters), plate, stainless steel 304/1.4301
  • SITRANS FUS SONO 3100/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 100 to DN 1200 (4" to 48"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, liquidcryogenic application, district heating systems. . DN600 / 24 Inch, Qn=3200m3/h EN1092-1 PN10 Carbon Steel. EN 1.0345 P235GH, Painted. IP67 PA housing, PN40, O-ring, 50mm, 100deg.C. Cable Glands, M20 in Transducers and M25 / M20 / M16 in FUS060 Transmitter. SITRANS FUS060 Transmitter for remote connection. Supply: 115-230 V AC 50/60 Hz. HART, 4-20mA, Active or Passive Pulse, Relay. Transducer Cable: 4 * 3 meter, Max. 70deg.C
  • SITRANS FUS SONO 3300/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 50 to DN 300 (2" to 12"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, hot water/cooling systems. . DN50 / 2 Inch Cast Steel, W1.1131 GS-16Mn5, Qn=10m3/h EN1092-1, PN40 flanges. EN 1.0025-S235JRG2. (DN 50 to 300 (2" - 12")) IP67 standard terminal box. Remote transmitter. No approval. . M20 in sensor terminal box and M25 / M20 / M16 in transmitter. SITRANS FUS060 Transmitter as remote version. Supply: 115-230 V AC 50/60 Hz. HART, 4-20mA, Active or Passive Pulse, Relay. Transducer Cable: 4 x 3 meter, Max. 70deg.C
  • SITRANS FUS SONO 3300/FUS060 2-track ultrasonic In-Line flowmeter, diameter DN 50 to DN 300 (2" to 12"). Suitable for volume flow measurement of liquids , for applications in water and treated wastewater, oil and liquefied gases, hot water/cooling systems. . DN50 / 2 Inch Cast Steel, W1.1131 GS-16Mn5, Qn=10m3/h EN1092-1, PN40 flanges. EN 1.0025-S235JRG2. (DN 50 to 300 (2" - 12")) . M20 in sensor terminal box and M25 / M20 / M16 in transmitter. SITRANS FUS060 Transmitter as remote version. Supply: 24 V AC/DC. HART-Version: With approval ATEX II 2G Ex dem (ia/ib) IIC T6/T4/T3. HART, Ex-version Ex. (ib), 4-20mA, Passive Pulse, Relay. Transducer Cable: 4 x 3 meter, Max. 70deg.C
0985225604
0985225604