7MC7511

  • 9,850,000VND 5,603,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell G 1/2" (1/2"BSPP) Insertion length untensioned: U = 301...400 mm Initial: 400 Diameter of the measuring tip: 6mm Extension length EU type: X = 65 mm (M = 81 mm) Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic"" gas / dust Length options: Specify special inst. length (in spec. area)
    Tải Xuống:
  • 14,039,000VND 7,985,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell G 1/2" (1/2"BSPP) Insertion length untensioned: U=1001...1250 mm Initial: 1250 Diameter of the measuring tip: 10 mm (6 mm line diameter) Please note: Insert can no longer be replaced. Extension length EU type: X = 65 mm (M = 81 mm) Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex for EU / Australia Transmitter: Sitrans TH100, Input: 1 x Pt100, Output: 4 … 20 mA Transmitter options: Specify measuring range in plain text
    Tải Xuống:
  • 16,661,000VND 9,476,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell NPT 1/2" Insertion length untensioned: U = 30...100 mm Initial: 100 Diameter of the measuring tip: 6mm Extension length EU type: X = 65 mm (M = 81 mm) Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -40 ... 1100Cel; Sensor quant., Type, Accuracy 2xTC N, Cl.2 -40 ... 1100Cel Requirements non-Ex for EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text
    Tải Xuống:
  • 7,259,000VND 4,129,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell NPT 1/2" Insertion length untensioned: U = 30...100 mm Initial: 100 Diameter of the measuring tip: 6mm Extension length EU type: X = 65 mm (M = 81 mm) Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.1 -40 ... 1000Cel Requirements non-Ex for EU / Australia
    Tải Xuống:
  • 32,427,000VND 18,444,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell NPT 1/2" Insertion length untensioned: U = 201...300 mm Initial: 300 Diameter of the measuring tip: 10 mm (6 mm line diameter) Please note: Insert can no longer be replaced. Extension length EU type: X = 65 mm (M = 81 mm) Alignable sensor spring at DIN measuring insert Connection head type: AH0; Aluminum; Screw cover; IP66/68 with displ. (4..20 mA) Ex d in combination with "E03"" Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -196 ... 600Cel; Extended measuring range Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex for EU / Australia Head cable inlet Connection head 1/2" NPT without cable gland; with head type AU0 and AH0 only IP66 Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)
    Tải Xuống:
  • 14,551,000VND 8,276,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell NPT 1/2" Insertion length untensioned: U = 201...300 mm Initial: 300 Diameter of the measuring tip: 6mm Extension length EU type: X = 65 mm (M = 81 mm) Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.A -30 ... 300Cel; Basic version Inspection certificate DIN EN 10204-3.1: Producer inspection certificate for Transmitter (5 measured values) Requirements non-Ex for EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text TAG plate TAG in plain text Stainless steel Length options: Specify special inst. length (in spec. area)
    Tải Xuống:
  • 20,818,000VND 11,842,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell M18x1,5 Insertion length untensioned: U= 200 mm Diameter of the measuring tip: 6mm Extension length EU type: X=151 ... 300 mm Initial: 300 Alignable sensor spring at DIN measuring insert Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -40 ... 1000Cel; Sensor quant., Type, Accuracy 1xTC K, Cl.2 -40 ... 1000Cel Requirements non-Ex for EU / Australia Transmitter: SITRANS TH300, HART, 4-20mA, universal Transmitter options: Specify measuring range in plain text
    Tải Xuống:
  • 16,245,000VND 9,240,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell M20x1,5 Insertion length untensioned: U = 201...300 mm Initial: 300 Diameter of the measuring tip: 6mm Extension length EU type: X = 139 mm (M = 155 mm) Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -40 ... 750Cel; Sensor quant., Type, Accuracy 1xTC J, Cl.2 -40 ... 750Cel Requirements non-Ex for EU / Australia Transmitter: SITRANS TH200, 4-20 mA, universal Transmitter options: Specify measuring range in plain text
    Tải Xuống:
  • 14,551,000VND 8,276,000VND
    SITRANS TS500 Temperature sensor in modular design, for installation in existing thermowells Material measuring insert: - for RTD: 316L/316Ti - for TC: Alloy 600 Design of the temp. sensor: For existing thermowells (with explosion protection, observe minimum thickness) Thread to the thermowell M20x1,5 Insertion length untensioned: U = 201...300 mm Initial: 300 Diameter of the measuring tip: 6mm Extension length EU type: X= 45 ... 150 mm Initial: 150 Alignable sensor spring at DIN measuring insert Connection head type: BA0: Aluminum; flange lid IP65 Meas. range:-200 ... 600Cel; Sensor quant., Type, Accuracy 2xPt100, Cl.B -196 ... 600Cel; Extended measuring range Requirements non-Ex for EU / Australia Transmitter: SITRANS TH100, 4-20 mA, for Pt100 Transmitter options: Specify measuring range in plain text Length options: Specify special inst. length (in spec. area)
    Tải Xuống:
  • 10,329,000VND 5,875,000VND
    SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BA0: Aluminum; flange lid IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex for EU / Australia Transmitter: Sitrans TH100, Input: 1 x Pt100, Output: 4 … 20 mA Transmitter options: Specify measuring range in plain text
    Tải Xuống:
  • 18,164,000VND 10,332,000VND
    SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BB0; Aluminum; Hinged cover small; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Explosion protection (ATEX, IECEx) For EU / Australia Intrinsic safety ia,"ic" gas / dust Transmitter: SITRANS TH200, 4-20 mA, universal Ex: ATEX/IEC Transmitter options: Specify measuring range in plain text
    Tải Xuống:
  • 6,300,000VND 3,583,000VND
    SITRANS TS500 Temperature sensor in modular design, tubular thermowell, 316Ti/1.4571 Process connection: Thread G 1/2" (1/2"BSPP) Thermowell form: 2/2G/2F acc. to DIN 43772; 2N; D= 9 Insertion length " mm " : 80...100 Initial: 100 Extension: Without Connection head type: BC0: Aluminum; Hinged cover high; IP65 Meas. range: -50 ... 400Cel; Sensor quant., Type, Accuracy 1xPt100, Cl.B -50 ... 400Cel; Basic version Requirements non-Ex for EU / Australia
    Tải Xuống:
0702026699
0702026699