SITRANS FC310 flowmeter system
-
127,468,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 1.5 with connection size 1/4 inch, Pipe thread ISO228-1 G, pressure PN365 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 125 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
127,468,000VND94,784,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 1.5 with connection size 1/4 inch, Pipe thread ISO228-1 G, pressure PN365 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 125 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
114,804,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
114,804,000VND85,368,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
179,529,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN350 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. ATEX II 2GD zone 1. FCT010/030 Field mount; z1/z21. MASS2100/FC300: Analog remote sensor z0/z1 MASS2100: Digital remote/compact sensor z1. No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
179,529,000VND133,498,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 3 with 1/4 inch female connector Pipe thread ISO228-1 G, pressure PN350 Hastelloy C22/ UNS N06022/ EN 2.4602 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. ATEX II 2GD zone 1. FCT010/030 Field mount; z1/z21. MASS2100/FC300: Analog remote sensor z0/z1 MASS2100: Digital remote/compact sensor z1. No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
153,882,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart FC300 Sensor DN4 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 115 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 10 meter analog signal cable 5 x 2 x 0.34 screened and twisted in pairs. Outside insulation blue PVC With two M20 connectors. Female/Female Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
153,882,000VND114,427,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart FC300 Sensor DN4 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 115 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 10 meter analog signal cable 5 x 2 x 0.34 screened and twisted in pairs. Outside insulation blue PVC With two M20 connectors. Female/Female Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
121,456,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 6 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
121,456,000VND90,315,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 6 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. Standard, no Ex approval No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with SensorProm for MASS6000/SIFLOW transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
151,643,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 6 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. ATEX II 2GD zone 1. FCT010/030 Field mount; z1/z21. MASS2100/FC300: Analog remote sensor z0/z1 MASS2100: Digital remote/compact sensor z1. No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with Sensor Flash cards (SD) for FCT010 and FCT030 transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)
-
151,643,000VND112,762,000VNDSITRANS MASS 2100/FC300 Single tube Coriolis flowmeter, diameter DI 1.5 (1/16"), DI 3 (1/8"), DN 4 (1/6"), DI 6 (1/4"), DI 15 (1/2"). Suitable for volume flow, fraction, mass flow, temperature and density measurement of liquids and gases. Coriolis sensor MASS2100 or FC300 sparepart MASS2100 Sensor Di 6 with 1/4 inch male connector Pipe thread ISO228-1 G, pressure PN100 AISI 316L / EN 1.4435 Max. media temperature 180 °C Standard calibration, Mass flow, 2 flow x 2 points Replacement sensor. No transmitter included. IP67 sensor enclosure. M23 socket for analog cable connection. ATEX II 2GD zone 1. FCT010/030 Field mount; z1/z21. MASS2100/FC300: Analog remote sensor z0/z1 MASS2100: Digital remote/compact sensor z1. No local user interface No cable glands Standard software (DSL/SIFLOW) No output channel No optional inputs and outputs on channels 2,3 and 4 Sensor with Sensor Flash cards (SD) for FCT010 and FCT030 transmitters
Tải Xuống:- Tài liệu kỹ thuật SITRANS FC MASS 2100 and FC300 DN 4 sensors (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT030 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT010 transmitter (Catalog)
- Tài liệu kỹ thuật MASS 2100 / FC300 DN 4 with FCT070 transmitter (Catalog)
- Hướng dẫn sử dụng SITRANS MASS 2100 & FC300 (FCT030) (Manual)